This listing hasn't been claimed by AcSoft Ltd - Headquarters & Training Centre yet — this item's details and price were compiled by JustVybe from publicly available sources and have not been checked or confirmed by the business.
Last updated 25 Nov 2026.
Last updated 25 Nov 2026.
SV 103 Hand-Arm Vibration Dosimeter – Standard
£2,713.85
Noise & Vibration Measurement Systems
SKU: ACSOFT-shop-929
Delivery & collection
Contact business to arrange
Check with the business for delivery charges, minimum orders and any address restrictions.
The SV 103 from Svantek significantly decreases the measurement uncertainty as the instrument is attached to the user’s arm and is small enough to take daily vibration exposure measurements without interfering with normal working activities.
The SV 103 uses our latest accelerometer, the SV 107B, that has a contact force sensor in addition to the standard accelerometer. Contact force is the sum of grip force and push force and is therefore a measurement of how firmly a user is holding the tool being measured. This is a recommendation of the new standards and the reading from the contact force sensor is also displayed on the screen. The SV 107B accelerometer is based on MEMS, the very latest in transducer technology. MEMS gives many advantages including shock resistance, very low power and frequency response down to DC. The usage of MEMS breaks the technological barrier of a weight and dimensions additionally reducing the cost of the complete system.
The SV 103 is powered using rechargeable batteries charged through the USB interface which also enables easy interconnection between the instrument and a PC. The measurement data is safely stored in the large 8 GB memory. The instrument works with our powerful “Supervisor” software which allows instrument configuration as well as the viewing and exporting of measurement data and daily vibration exposure recalculations.
The colour OLED screen that offers excellent visibility even in full daylight completes the exceptional features of this instrument.
Features
Reports directly into Supervisor for data management and reporting
Includes force measurement
Robust MEMS microphone technology
Correct way to measure HAVS due to sensor placement
Valid to both ISO 8041/1 & 8042/2 standards
Additional technical information:
SV 103 Personal Human Vibration Exposure meter is dedicated to hand-arm vibration measurements. The instrument meets ISO 8041:2005 and is the ideal choice for making measurements according to ISO 5349 and European Directive 2002/44/EC.
Hand-arm vibration is when mechanical vibrations are transmitted to the human hand when in contact with the surface of a vibrating machine such as an electric drill. This type of vibration is particularly harmful as it can cause pathological changes in the nervous system of the hands and fingers; commonly called white finger disease. As there is no cure for damage caused by vibration, the only effective regime is to take regular vibration measurements in the hazardous workplace environment and therefore ensure that damage is not caused in the first place. However, many currently used assessment methods for hand-arm vibration are subject to a very high level of uncertainty and typically vibration measurement accuracy can vary in the range of ±20% to 40% which makes a big difference in terms of white finger disease. The SV 103 from Svantek significantly decreases the measurement uncertainty as the instrument is attached to the user’s arm and is small enough to take daily vibration exposure measurements without interfering with normal working activities.
The SV 103 uses our latest accelerometer, the SV 107B, that has a contact force sensor in addition to the standard accelerometer. Contact force is the sum of grip force and push force and is therefore a measurement of how firmly a user is holding the tool being measured. This is a recommendation of the new standards and the reading from the contact force sensor is also displayed on the screen. The SV 107B accelerometer is based on MEMS, the very latest in transducer technology. MEMS gives many advantages including shock resistance, very low power and frequency response down to DC. The usage of MEMS breaks the technological barrier of a weight and dimensions additionally reducing the cost of the complete system.
The SV 103 is powered using rechargeable batteries charged through the USB interface which also enables easy interconnection between the instrument and a PC. The measurement data is safely stored in the large 8 GB memory. The instrument works with our powerful “Supervisor” software which allows instrument configuration as well as the viewing and exporting of measurement data and daily vibration exposure recalculations.
The colour OLED screen that offers excellent visibility even in full daylight completes the exceptional features of this instrument.
Personal Daily Vibration Exposure Meter
Vibration meter
StandardsISO 8041:2005, ISO 5349-1:2001; ISO 5349-2:2001
Meter modeRMS, Max, Peak, Peak-Peak, Vector, A(8) Daily Dose, ELV, EAV
Simultaneous measurement in three channels
FiltresWh (ISO 5349) and corresponding Band Limiting filter
RMS & RMQ DetectorsDigital true RMS & RMQ detectors with Peak detection, resolution 0.1 dB
Measurement Range0.2 ms-2 RMS ÷ 2000 ms-2 PEAK
Frequency Range1 Hz ÷ 2000 Hz
Data LoggerTime-history data including meter mode results and spectra
Time-Domain RecordingSimultaneous 3-channel time-domain signal recording (option)
Analyser1/1 octave real-time analysis meeting Class 1: IEC 61260 (option)
1/3 octave real-time analysis meeting Class 1: IEC 61260 (option)
Accelerometerdetachable SV 107B tri-axial accelerometer with hand straps in accordance to ISO 5349
Basic data
DisplayOLED 128 x 64 pixels
Memory8 GB
InterfacesUSB 2.0 client
Keyboard4 push buttons
Power SupplyNi-MH rechargeable cells: operation time > 24 hours1
USB interface: 500 mA HUB
Environmental ConditionsTemperature: from -10 oC to 50 oC
Humidity: up to 90 % RH, non-condensed
Dimensions88 x 49.5 x 19.2 mm (instrument without accelerometer, cable and mounting stripe)
Weight150-160 grams with SV 107B accelerometer and one of vibration contact adapters
SV 103 Datasheet
Declaration of Conformity
Accessories available for the SV 103 Personal Vibration Monitor:
Power supply unit by USB interface using cables SC 16 or SC 56 (cables not included)
SA 54
Vibration calibrator for HVM
SV 111
Hand-Arm triaxial accelerometer including adapter and contact force sensor for SV 103
SV 107D
Micro USB cable
SC 156
Armband fixing for SV 103 dosimeter
SA 103
Carrying case for SV 103 and accessories (waterproof)
SA 76
Band for cable fixing of SV 103 dosimeter
SA 107
Hand-Arm measure. adapter, shaped base for SV 105B, SV105BF
SA 150B
Hand-Arm measure. adapter, flat base for SV 105B, SV105BF
SA 152B
For more details or to order accessories for the SV 103 Personal Vibration Monitor, get in touch with our team.
Configuration: Standard
Hand-Arm vibration dosimeter including SA 76 hard carry case
Published shop price: £2,261.54 excluding VAT. Catalogue price: £2,713.85 including VAT at 20%.
Supplier availability: available on back-order; confirm delivery times.
Confirm specification, current price and lead time with AcSoft.
Supplier shop: https://shop.acsoft.co.uk/product/sv-103-hand-arm-vibration-dosimeter/
Catalogue item — contact the business to enquire.
Back to shop