This listing hasn't been claimed by AcSoft Ltd - Headquarters & Training Centre yet — this item's details and price were compiled by JustVybe from publicly available sources and have not been checked or confirmed by the business.
Last updated 25 Nov 2026.

SV 102A+ Class 1 Dual Channel Dosimeter – Standard

£3,048.00

Noise & Vibration Measurement Systems

SKU: ACSOFT-shop-956

Delivery & collection

Contact business to arrange

Check with the business for delivery charges, minimum orders and any address restrictions.

The SV102A+ is a dual-channel noise dosimeter designed for the accurate measurement of noise exposure to ISO 9612, OSHA and NIOSH standards. The two channel technology allows for noise exposure levels to be assessed simultaneously on both sides of the head. The meter meets class 1 requirements of IEC 61672 and it can be used when measuring at very low temperatures (from -10 C) or when noise is dominated by high frequencies as it is recommended by ISO 9612. The colour digital display is an OLED screen with a high contrast visibility even in full daylight or in low ambient light areas. It displays information in both text and graphical form. The auto-calibration facility makes the SV102A+ very easy to use. Once the instrument detects the calibration signal it starts the calibration process automatically, saving the calibration data together with the measurement file, both before and after measurement. The time history logging of results such as Leq, Max, Min and Peak with two simultaneous logging steps is saved in 8 GB memory. All dosimetry results such as DOSE, TWA, LAV are also included. The small and compact SV 15 preamplifier together with special mounting clip and dedicated headband enables an easy attachment of the microphone in extremely short distance to human ears. Calibration by measurement can be easily performed by direct usage of common acoustic calibrators. SV 102A+ is also able to perform the measurement inside human ear – with the usage of SV 25S – smart microphone with an automatic calibration function (TEDS). The SV 102A+ together with SV 25S are designed for individual real-world test of the earmuffs noise reduction ratio by means of MIRE technique (Microphone-In-Real-Ear)-measurements under headphones or earmuffs. With a special adaptor, SV 25S can be also calibrated with available acoustic calibrators. Features Class 1 Dual channel input Auto calibration Unique opportunity to assess the exposure on both sides of the head simultaneously Additional technical information: The SV 102A+ is a Class 1 dual-channel noise dosimeter, integrating two distinct functionalities: dual-channel noise measurement and Class 1 frequency range capability. The dual-channel feature allows for simultaneous noise exposure assessment on both sides of the head or in configurations such as underneath a headset and on a shoulder, enhancing the accuracy of noise exposure data in diverse working environments. This capability is particularly beneficial for assessing asymmetric noise exposure, where noise may predominantly come from one direction. Class 1 accuracy of the SV 102A+ signifies its ability to measure a full frequency range from 20 Hz to 20 kHz. This is a critical feature for workplaces with high-frequency noise sources, as standard Class 2 dosimeters typically measure up to only 8 kHz. The wider frequency range makes sure that the instrument meets the requirements of ISO 9612 for Class 1 instruments, which is important for accurate noise assessment in places where there is a lot of high-frequency noise. The SV 102A+ also features audio recording, facilitating unattended noise measurements. This capability allows for the playback of recorded noise to identify and verify noise sources, a requirement under ISO 9612 for distinguishing work-related noise from non-work-related noise sources. Additionally, the dosimeter’s 1/1 octave analysis feature enables the precise selection of hearing protectors based on the specific noise environment, further enhancing workplace safety. MIRE Measurement with SV 102A+ MIRE (Microphone in Real Ear) measurement is a specialized technique used with the SV 102A+ for assessing noise exposure from sources in close proximity to the ear, such as in call centers, pilot helmets, and headsets. This method involves placing a specialised microphone probe, the SV 25S, at the entrance of the ear canal to accurately capture the noise exposure experienced by the individual. The SV 102A+ supports 1/3 octave analysis for MIRE measurements, a requirement to meet ISO 11904-1 standards for recalculating noise doses based on actual noise levels inside the ear canal. For MIRE measurements, the SV 102A+ utilizes a high sampling rate of 48 kHz, consistent with Class 1 instrumentation standards. This high sampling rate is essential for capturing the full spectrum of noise frequencies encountered in close-ear environments, ensuring accurate and reliable noise exposure assessments. The small and compact SV 15 preamplifier together with special mounting clip and dedicated headband enables an easy attachment of the microphone in extremely short distance to human ears. Calibration by measurement can be easily performed by direct usage of common acoustic calibrators. The combination of dual-channel measurement, Class 1 frequency range capability, and MIRE measurement technique positions the SV 102A+ as a preferred instrument for noise exposure assessment in military, aerospace, and call center applications worldwide. Its comprehensive features ensure that it meets the stringent requirements for noise measurement and analysis in these specialised fields. Dual-Channel Input The SV102A+ features two input channels which allows for the concurrent use of dual microphones. This comprehensive dual- channel approach allows you to measure noise exposure evaluation from both sides of the head. It also allows you to place one microphone on the shoulder, one in the ear canal and combine the measurements. Such configurations are invaluable for accurately assessing the attenuation efficiency of hearing protectors and evaluating the acoustic performance of communication headsets, including those used in demanding environments such as military aviation, where reliable noise reduction and speech intelligibility are critical. This feature highlights the versatility of the SV102A+ in adapting to a range of measurement scenarios, further enhancing its utility in occupational noise assessment. SV 102A+ Class 1 Dual Channel Dosimeter Specification StandardsIEC 61252; ANSI S1.25-1991; Class 1: IEC 61672:2002, ISO 11904-1 Acoustic Dosimeter ModeLav/Leq, SPL, Lmax, Lmin, SEL, SEL8, PSEL, LEPd, Dose (%), TWA, E, E_8h, Peak, Run Time, Upper Limit Time (ULT), L(C-A), Projected Dose (D_8h) SLM ModeLeq, Spl, SEL, LEP,d, Lden, Ltm3, Ltm5, statistics – Ln (L1- L99), LMax, LMin, LPeak Simultaneous measurement in three profiles with independent set of filters and detectors Weighting FiltersA, C and Z RMS DetectorDigital true RMS detector with Peak detection, resolution 0.1 dB Time constants: Slow, Fast, Impulse MicrophoneSV 7052E, prepolarised, 1/2″ housing SV 25S, special microphone with dedicated probe for Microphone-In-Real-Ear technique (option) PreamplifierSV 15 with integrated cable Measurement Range45 dBA RMS ÷ 141 dBA Peak (with SV 7052E microphone) Typical noise floorless than 35 dBA Frequency Range20 Hz ÷ 20 kHz, sampling rate 48 kHz Dynamic Range100 dB Data Logger1Time-history logging of Leq/Lmax/Lmin/Peak/Lav results to internal memory with time step down to 100 millisecond to microSD card Audio Recorder1Time-domain signal events recorder (option) Dual-channel ModeDual-channel measurement mode with second microphone SV 7052E or SV 25S (option) 1/1 Octave1Dual-channel 1/1 octave real-time analysis and spectra logging, 10 filters with centre frequencies from 31.5 Hz to 16 kHz, Type 1: IEC 61260 (option) 1/3 Octave1Dual-channel 1/3 octave real-time analysis and spectra logging, 31 filters with centre frequencies from 20 Hz to 20 kHz, Type 1, IEC 61260 (option) Basic Data Input2 x LEMO 2-pin, Direct DisplayColour 160 x 128 pixels OLED type MemoryMicroSD card 8 GB (removable & upgradeable) InterfacesUSB 1.1 Client Extended I/O – AC output (1 V Peak) / Digital Output (Alarm trigger) / Digital Input (Input trigger) Power SupplyTwo AA batteries (alkaline): operation time > 16 h (3.0 V / 1.6 Ah)2 Two rechargeable batteries (not included): operation time > 20h (2.4 V / 2.6 Ah)2 USB interface: 150 mA HUB Environmental ConditionsTemperature: from -10 oC to 50 oC Humidity: up to 90 % RH, non-condensed Dimensions95 x 83 x 33 mm (without microphones) Weight260 grams with batteries (without microphones) 1function parallel to the acoustic dosimeter mode or meter mode 2depends on instrument operation mode *Continuous product development and innovation are the policy of our company. Therefore, we reserve the right to change the specifications without prior notice. SV 102A+ datasheet SV 102A+ User Manual Accessories available for the SV 102A+ Class 1 Dual Channel Dosimeter: Mini USB cable SC 56 Dosimeter preamplifier with TEDS, integrated cable for SV 102A SV 15 Prepolarised condenser microphone cartridge 1/2″ / 32 mV SV 7052E Class 1 acoustic calibrator: 1000 Hz/114 dB SV 33B For more details or to order accessories for the SV 102A+ Class 1 Dual Channel Dosimeter, get in touch with our team. Configuration: Standard Dual channel noise dosimeter, including one SV 15 preamplifier with cable, SV 7052E microphone and SA 142 case. Published shop price: £2,540.00 excluding VAT. Catalogue price: £3,048.00 including VAT at 20%. Confirm specification, current price and lead time with AcSoft. Supplier shop: https://shop.acsoft.co.uk/product/sv-102a-class-1-dual-channel-dosimeter/
Catalogue item — contact the business to enquire. Back to shop