CRY8124 Acoustic Camera
Price on application
Acoustic Imaging
SKU: ACSOFT-main-13759
Delivery & collection
Contact business to arrange
Check with the business for delivery charges, minimum orders and any address restrictions.
The CRY8124 Acoustic Imaging Camera helps maintenance and engineering teams locate compressed air and gas leaks, investigate electrical partial discharge and identify industrial sound sources.
Using a 200-microphone array with a frequency range of 2kHz to 100kHz, it displays acoustic information over a camera image, helping users pinpoint areas that require further investigation.
Check out our range of cameras with our acoustic camera comparison page
The CRY8124 is available with a variety of accessories, each offering additional features to enhance the capabilities of the acoustic camera.
You can explore the full range in the Accessories tab, including options such as the IA3104 and IA3105 ultrasonic sensor probes, which provide a handheld solution for capturing high-frequency acoustic signals generated by internal leaks within valves.
Setting a new standard for sensitivity and efficiency, the CRY8124 boasts 200 microphones. The device detects smaller leaks and partial discharges from greater distance than any other handheld acoustic imaging camera on the market. The CRY8124 reporting software allows offline analysis, editing, and report generation, simplifying regular maintenance routines.
With 200 microphones, 100kHz bandwidth, and the fastest processor in the industry, the CRY8124 can pinpoint smaller leaks and partial discharges at a greater distance than any other system. Keeping operators at a much safer distance, avoiding exposure to toxic gases. Also, benefiting from the increased detection distance, the camera covers a wider area, improving test efficiency by more than 4 times.
Detectability of Sound Sources in Noisy Environments
In most field inspections, background noise is always the biggest concern that limits the performance of acoustic imaging cameras. With the CRY8124, we have introduced a new powerful algorithm, ‘HyperVision.’ This mitigates mutual interference between different sources. The signals of the target sound source are emphasised, and previously unrecognized sound sources are accurately identified and presented.
Thermal & Acoustic Imaging Display Simultaneously
Integrating infrared technology with an acoustic camera significantly boosts its capabilities and efficiency. This combination enables real-time, simultaneous visualization of both thermal and acoustic images, ensuring that no detail goes unnoticed. By eliminating the need for separate thermal and acoustic inspections, it streamlines workflows and enhances overall inspection efficiency. This integration is especially valuable in high-temperature scenarios, such as with steam traps, where precise temperature measurement aids in informed decision-making. Resolutions of 640×512 and 384×288 available and measurement range from -20 to 500℃ .
Up to 10 Hours of Operation with Replaceable Battery
The acoustic imaging camera comes with advanced replaceable batteries, enhancing convenience and extending operational time. Each battery provides up to 5 hours of continuous use, ensuring uninterrupted inspections. With an extra spare battery included, the device supports a full day of testing. The standard package features two smart batteries and a smart battery charger for effortless battery management. LED indicators on each battery show the current charge level, allowing users to easily monitor battery status and plan their work efficiently.
Advanced Reporting Software
Paired with advanced reporting software that significantly enhances user experience and efficiency. The software boasts a newly redesigned, intuitive interface, making navigation and operation easier than ever. Wireless data transfer capabilities allow users to seamlessly send inspection data from the camera to the software, eliminating the hassle of cables. Additionally, the software supports infrared data analysis and provides powerful tools for data post-processing, enabling comprehensive investigations and the creation of detailed reports.
Acoustic Specification
Microphone array200 channels MEMS microphone
Frequency range2k – 100k Hz
SPL range28 – 132 dB
Minimum detectable leak10 m: 0.0022 L/min, 5.6 bar 0.5m: 0.0015 L/min, 5.6 bar
Test distance0.2 – 240m (1 – 787 ft)
Camera
Camera FOV120°(D) 94°(H) x 76°(V)
Focal length2.3mm (0.09 inches)
Camera pixel13M pixel
Digital zoom1x – 6x
Fill lightLED * 4
Display
Resolution1920 * 1200 (6 x digital zoom)
Size8 inches
TouchscreenCapacitive touchscreen
Brightness600 nits, support auto and manual adjustment
Storage
Storage64G internal,64G external TF card
Data format.jpg (picture),.mp4 (video),.wav (audio),.cdat(data)
Video length10 minutes
Date exportUSB-C,Wi-Fi,TF card
General Specifications
Size270 * 190 * 51 mm (10.6 * 7.5 * 2.0 inches)
Weight1.5 kg (3.31 lbs)
BluetoothBT 5.2
Storage size64G internal,64G external
Certificate
SafetyIEC 61010-1
EMCIEC 61326-1
Vibration2g,IEC 60068-2-6
Shock25g,IEC 60068-2-27
Hardware
USB-C 1USB 3.0 for charging,HDMI,data export
3.5 mm audio jackHeadphone output
SIM card slotInserting a 4G/5G network communication card
Analog input4 channels,20 – 100k Hz,IEPE,phantom power supply
CRY8124 Leaflet
CRY8124 Datasheet
How does the CRY8124 Work
IA3104 Contact Ultrasound Probe Datasheet
CRY8124 User Manual_V1.3
IA3105 EX Contact Ultrasound Probe Datasheet
Valve Internal Leak Detection Guide – YouTube
Accessories available for the CRY8124 Acoustic Camera:
Thermal Imaging Adaptor Lower Res
CRYIA1301
Thermal imaging adaptor Higher Res
CRYIA1302
Smart Battery Pack
CRYIA2001
Dual Battery Pack
CRYIA2101
Ultra Sonic Sound Source
CRYIA1101
Contact Ultrasound Sensor
IA3104 – Built for leak detection in valves, handling pressurized gases and liquids. The IA3104 utilizes advanced ultrasonic sensing technology to precisely capture high-frequency acoustic signals generated by internal leaks within the valves. The IA3104 is compatible with our CRY8124 and the CRY8125
Ex Contact Ultrasound Sensor
IA3105 – Built for leak detection in valves handling pressurized gases and liquids. The IA3105 ultilzes ultrasonic sensing technology while also being TUV certified making it ideal for use in explosive atmospheres. The IA3105 is fully certified under IECEx and ATEX. The IA3105 is compatible with our CRY8124 and the CRY8125
For more details or to order accessories for the CRY8124 Acoustic Camera, get in touch with our team.
Price on application. Contact AcSoft to confirm the required model, configuration, accessories, licensing, availability and delivery terms.
Official product information: https://acsoft.co.uk/product/cry8124-acoustic-imaging-camera/
Manufacturer documents:
How does the CRY8124 Work: https://acsoft.co.uk/wp-content/uploads/2024/09/How-does-the-CRY-8124-Work_compressed.pdf
CRY8124 Datasheet: https://acsoft.co.uk/wp-content/uploads/2024/09/CRY8124-Datasheet.pdf
IA3104 Contact Ultrasound Probe Datasheet: https://acsoft.co.uk/wp-content/uploads/2026/10/IA3104-Contact-Ultrasound-Probe-Datasheet.pdf
CRY8124 User Manual_V1.3: https://acsoft.co.uk/wp-content/uploads/2024/09/CRY8124-User-Manual_V1.3.pdf
IA3105 EX Contact Ultrasound Probe Datasheet: https://acsoft.co.uk/wp-content/uploads/2026/10/IA3105-EX-Contact-Ultrasound-Probe-Datasheet.pdf
Catalogue item — contact the business to enquire.
Back to shop